Javscript would provide a navigation menu here. HOME
ActiveSync Scripting
The following is a nice? sample for an automation task. This batch is like
the one in Tipps.
It will be executed every time a device connects to your PC via ActiveSync.
You will need the itsutils.
As you can read, the batch (script) first tries to check, if it has already
been run on the device. This is done by looking for a file called "\OnConnect.done".
In real, the batch deletes a local file (line 13) "OnConnect.done"
and then simply copies the file from the device (line16). If the file is found,
this device has been already processed (line 17) and the batch gos on with line
66.
If the file is not found, the batch continues with setting the registry changes.
It uses saved REG files and the nice tool pregutl to do it remotely (line 22
to 24). After doing the changes, the device will be queried for different registry
keys which will be saved to database.txt for later use. The registry keys platform
(line 29) and version (line 30) are available on all devices, but OSBuildInfo
(line 59) and system (line 48) are only available on CK3x or 7xx.
So in line 33, we try to find the model string for CK3x devices and in line
39 for CN2 devices. In line 43 and 44 we will use the saved model names to jump
over the part, that is only valid for PPC (7xx): dump psminfo.txt into database.txt.
The OSBuildInfo registry is only been executed for CK3x models.
Finally we put a OnConnect.done onto the device, so we later know, that it
was handled. At the very end, we sync the time of the device with the PC.
@echo off
cls
echo ######################################################################
echo # autosetup script for ITC devices (CK3x, CN2x, 7xx) #
echo # will set registry keys for numberig format, timezone and DST #
echo # creates a database.txt file with relevant data of the devices #
echo ######################################################################
D:
cd \OnConnect
echo "checking if already processed device..."
REM check if already processed
REM delete the check file
@del OnConnect.done >NULL
echo onconnect >OnConnect.bak
REM try to load the checkfile
@pget \OnConnect.done >NULL
if exist OnConnect.done goto OldDevice
goto NewDevice
:NewDevice
echo "####### New Device #######"
echo "setting region..."
pregutl @region.reg
echo "setting timezone..."
pregutl @timezone.reg
REM put device in database
echo. >>database.txt
echo "building database entries..."
echo ####### >>database.txt
pregutl HKEY_LOCAL_MACHINE\Platform >>database.txt
pregutl HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\Version >>database.txt
REM only PPC device have Intermec\System
REM check for ck3x
pregutl HKEY_LOCAL_MACHINE\Platform | FINDSTR "CK3"
if errorlevel 1 goto cont1
if errorlevel 0 set Model="CK3X"
:cont1
REM CN2 does not have OSBuildInfo as CK3x
REM check for CN2
pregutl HKEY_LOCAL_MACHINE\Platform | FINDSTR "CN2"
if errorlevel 1 goto cont2
if errorlevel 0 set Model="CN2"
:cont2
if "%Model%"==""CK3X"" goto CK3x
if "%Model%"==""CN2"" goto CN2
REM PPC only
:NoCK3x
:NoCN2
pregutl HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\System >>database.txt
REM look for PSMInfo
del PSMInfo.txt
pget "\Flash File Store\PSMInfo.txt"
if NOT EXIST PSMInfo.txt goto NoPSM
type PSMInfo.txt >>database.txt
echo. >>database.txt
REM if you like to get a listing of the cabfiles uncomment following line
REM pdir "\Flash File Store\Persistent Copy\Cabfiles\*.*" >>database.txt
goto NoPSM
:CK3x
pregutl HKEY_LOCAL_MACHINE\SOFTWARE\Intermec\OSBuildInfo >>database.txt
:NoPSM
:CN2
pput OnConnect.bak \OnConnect.done
REM the database will be filled once
REM reg changes will also done only for new devices
REM psynctime will be executed always
:OldDevice
REM uncomment, if you like to get a list of installed apps
REM pregutl HKEY_LOCAL_MACHINE\SOFTWARE\Apps >>database.txt
echo "syncing time..."
psynctime
@echo on
REM pause DEBUG
:EXIT
exit